Sending commands to AutoCAD command line now has two variants of the earlier acedCommand method. The acedCommandS is simpler to use and suitable when all the parameters (a.k.a tokens) that are required by AutoCAD to complete the command execution are known without a need for user input. When using acedCommandS by providing all the parameters, there is no possibility of cancelling the command.
acedCommandC is to be used when you need AutoCAD to pause for some user input while is command is run by AutoCAD. In this case, there is a possibility of user cancelling the command without providing the input. To identify this condition, here is a code snippet that uses the “acedCmdCWasCancelled” and “acedCallBackOnCancel” methods. Also, due to the asynchronous nature of acedCommandC, the completion of the command can only be identified from the callback method provided to acedCommandC as in this code snippet.
#include "acedCmdNF.h"
static void AdskMyTestCommand()
{
ads_point pt1;
int rt = ads_getpoint(
NULL,
_T("nSelect first point: "), pt1);
int rs = acedCommandC
(
&MyCallback,
NULL,
RTSTR,
_T("_line"),
RT3DPOINT,
pt1,
RTNONE
);
acutPrintf(ACRX_T("nAfter acedCommandC call.
acedCommandC is asynchronous..."));
}
static int MyCallback(void * pData)
{
if (acedCmdCWasCancelled())
{
acutPrintf(ACRX_T("nCommand was cancelled..."));
return 0;
}
if(isLineActive())
{
int rs = acedCommandC
(
&MyCallback,
NULL,
RTSTR,
PAUSE,
RTNONE
);
acedCallBackOnCancel();
return 1;
}
CallWhenLineDone();
return 0;
}
static void CallWhenLineDone()
{
acutPrintf(ACRX_T("nCommand completed."));
}
static Adesk::Boolean isLineActive()
{
struct resbuf rb;
acedGetVar(_T("CMDNAMES"),&rb);
if (_tcsstr(rb.resval.rstring, _T("LINE")))
return Adesk::kTrue;
return Adesk::kFalse;
}